GoldenEyeFixes 2016.1 R1

From DigitalVision
Jump to: navigation, search

GoldenEye Fixes

2016.1.019

  • GE-212 Overwriting existing audio file will make the scanner stop recording
  • GE-280 Wrong labelling on sprocket wheel 65
  • GE-292 Moving between different settings tabs resizes diagrams panes with 'show zoom' enabled
  • GE-416 Image freezes when using the scroll bars in Zoom mode
  • GE-478 Storage Format: tiff big endian auto and 16bit bit grayscale export corrupt image
  • GE-481 Changing from 4K A35mm to 2K A35mm in the same session will crash the system during the shading calibration
  • GE-485 Golden Eye software always adds quarter or half a frame extra to scanned sequence
  • GE-487 Shading calibration calculates negative reference exposures
  • GE-535 Clean Scanner pop up window needs updating
  • GE-555 Sync problem with clear film base where the threshold of the perforation isn't correct
  • GE-567 LED Voltage Supply Turn Off Command
  • GE-571 Error about film definitions file after turning on the scanner
  • GE-573 LED Calibration Error appearing on startup
  • GE-576 Change default output from Lin to Log/Use Dmin and Dmax when opening a new session
  • GE-600 Remove pop up windows during a 8-Piece Shading Calibration
  • GE-601 Hide in the developers mode GUI Output Lin Status, Log Status and Log Raw
  • GE-602 Fine Line problem when scanning faster then 8fps
  • GE-622 When installing the Gecko - the terminal reports OK - but the Windows install message remains open
  • GE-623 When installing the Gecko the terminal reports that drivers failed to load
  • GE-626 With a BMD vid card installed GE4 can only use the default file format
  • GE-636 Crash caused by entering zoom mode with RGB zooming enabled
  • GE-650 Rename "Overview Speed" to be "Play Speed"
  • GE-664 Software Crashing on recording with timecode
  • GE-670 Crash on opening session or creating new session while playing or recording
  • GE-672 For all up or downloads - detect and list errors and show progress

Gecko

  • GE-443 When using Go To and rewind the framing is off by one frame
  • GE-492 Wheeldata file needs to be updated for 9.5mm film in Gecko
  • GE-555 Sync problem with clear film base where the threshold of the perforation isn't correct
  • GE-602 Fine Line problem when scanning faster than 8fps
  • GE-614 When using Go To in rewind the accuracy is less when spooling over 2500 frames
  • GE-622 When installing the Gecko - the terminal reports OK - but the Windows install message remains open
  • GE-645 Step forward or backward doesn't update the image view
  • GE-665 Goto doesn't consistently update the image view with the landing frame
  • GE-674 Using Go to from 0 to 499 with auto sync the frame a perf out
  • GE-675 Using Set forward or backwards with auto sync doesn't update the monitor and the counter jumps a couple of frames